|
Odour Control, Industrial Processes |
| Oct 2014 |
Rugged, chemical free |
|
|
|
Odour control in chemical plant |
|
Features | Applications |
| |
| |
| |
| |
| |
- couples directly to existing ductwork
| |
- up to 30 g/hr output for effluent flows of 5000 m3/hr
|
|
|
|
|
Ozone |
|
One very effective way of producing ozone is using targeted energy plasma which gives some O2 molecules enough
energy to split in two and combine with other O2 molecules, making O3 which is ozone.
Ozone is also produced naturally by lightning and one property it has is that it neutralises smells, which is why everything smells
so fresh after a thunderstorm. Another property of ozone is as a sanitiser as it kills bacteria, viruses and mould. Ozone is more
powerful than chlorine but unlike chlorine, it: |
|
- does not linger
- does not contaminate the environment
|
|
Specification |
|
| Model 2T | Model 4T |
Ozone output at optimum airflow rate (g/hr) | 15 |
30 |
Ozone optimum airflow rate (m3/hr) |
300 | 600 |
Ozone maximum airflow rate (m3/hr) |
375 | 750 |
Effluent optimum heavy odour airflow rate (m3/hr) |
1500 | 3000 |
Effluent optimum light odour airflow rate (m3/hr) |
2500 | 5000 |
Est. pressure drop at optimum ozone airflow with clean filters (Pa) |
200 | 500 |
Est. pressure drop at optimum ozone airflow with 50% blocked filters (Pa) |
400 | 700 |
Power consumption (W ) | 200 | 320 |
Weight (kg) | 46 | 55 |
Enclosure dimensions approx (mm) |
647 x 435 x 245 | 750 x 530 x 300 |
Ozone outlet | Nominal 100mm dia |
Enclosure material | Fibreglass enriched polyester |
Features | |
- Counter records total operating time
|
|
|
|
| |
Warranty | 1 Year |
|
Safety Features |
|
- Semi/automatic circuit breaker
|
|
- Differential pressure regulators
|
- High flammability resistance
|
|